Sequencer Timer for Dust Collector (STANDARD Solution)
| Model |
SDT-8M ,STD-16M , STD-24M
STD-8AT , STD-16AT , STD-24AT |
| Power supply voltage |
230 Vac 50-60 Hz ± 10 % |
| Output voltage |
230 Vac 50-60 Hz
24 Vdc (Optional) |
| Inputs |
Remote enabling (Jumper Terminal [CONTROL IN]
Post-cleaning cycles fan switch. (Terminal [FAN]) |
| Solenoid valves output |
8 , 16 , 24 |
| Electric consumption |
28 Watts at maximum load |
| Alarm Relays |
1 Point normally open (Terminal [ALARM]) , AT model |
| Maximum load |
3A @ 250Vac,
2A @ 24Vdc, |
| Screen |
LCD display |
| 5 x 20 mm glass fuse |
230 Vac 1 x 2 A
24 Vdc 1 x 2 A |
| Operating temperature |
-10 °C - 55 °C |
| Differential pressure |
0-10 Kpa (2 point setting)
, AT model |
| Casing |
Base in ABSLid in Polycarbonate |
|
|
Sequencer Timer for Dust Collector (ECO Solution)
| Model |
ECO-4M ,ECO-8M , ECO-12M,-ECO-16M
ECO-4AT , ECO-8AT , ECO-12AT , ECO-16AT |
| Power supply voltage |
230 Vac 50-60 Hz ± 10 % |
| Output voltage |
230 Vac 50-60 Hz
24 Vdc (Optional) |
| Inputs |
Post-cleaning cycles fan switch. (Terminal [FAN]) |
| Solenoid valves output |
4 , 8 , 12 , 16 |
| Electric consumption |
28 Watts at maximum load |
| Alarm Relays |
1 Point normally open (Terminal [ALARM]) , AT model |
| Maximum load |
3A @ 250Vac,
2A @ 24Vdc, |
| Screen |
LCD display |
| 5 x 20 mm glass fuse |
230 Vac 1 x 2 A
24 Vdc 1 x 2 A |
| Operating temperature |
-10 °C - 55 °C |
| Differential pressure |
0-10 Kpa (2 point setting)
, AT model |
| Casing |
Base in ABSLid in Polycarbonate |
|
|
Sequencer Timer for Dust Collector (BUDGET Solution)
| Model |
BUD-6M , BUD-12M |
| Power supply voltage |
230 Vac 50-60 Hz ± 10 % |
| Output voltage |
230 Vac 50-60 Hz
|
| Inputs |
Post-cleaning cycles fan switch. (Terminal [FAN]) |
| Solenoid valves output |
6 , 12 |
| Electric consumption |
28 Watts at maximum load |
| Maximum load |
3A @ 250Vac,
|
| Screen |
LCD display |
| 5 x 20 mm glass fuse |
230 Vac 1 x 2 A
|
| Operating temperature |
-10 °C - 55 °C |
| Casing |
No |
|
|
Turbo Sequencer Timer 
E1T , E2T control unit economiser 4-24 output channels
| Power supply voltage |
115 Vac 50-60 Hz ± 10 %
230 Vac 50-60 Hz ± 10 % |
| Output voltage |
115 Vac 50-60 Hz
230 Vac 50-60 Hz
24 Vac
24 Vdc |
| Inputs |
Remote enabling
consent switch.
Post-cleaning cycles
fan switch. |
| Solenoid valves output |
4 , 8 , 12 ,16 ,20, 24 |
| Electric consumption |
28 Watts at maximum load |
| Alarm Relays |
2 normally closed
Maximum load: 3A @ 250Vac,
2A @ 24Vdc, 24 Vac. |
| Active output 4-20ma |
Proportional to the dP reading for
remote consultation of the pressure. |
| Screen |
LCD display |
| 5 x 20 mm glass fuse |
115 or 230 Vac 1 x 1 A
24 Vac or 24 Vdc 1 x 3 A |
| Operating temperature |
-10 °C - 55 °C |
| Differential pressure |
0 - 4 kPa |
| Casing |
Base in ABS
Lid in Polycarbonate |
|
|
|